1. Qty. 1 Second-hand Electric Arc Furnace 

1974 The original EAF was build in 1974 by Mannesmann Demag as a 30 t tapping weight furnace.

 

1983 Revamp of the upper shell to water cooled panels and larger diameter (4,6 m), siphon type tapping

 
1990 Installation of water cooled roof (panel design) 

1992 Installation of 37/44,4 MVA ABB Transformer, Reactor and ABB Electrode Regulation System

 
(increase of voltage from 400 to 670 V sec., 50 Hz) 
1996/97 Complete revamp of transformer 2002 Last year of operation 
- UHP EAF – siphon type (1983), Demag - Tapping weight 45 – 50 ton 
- EAF diameter (upper shell) – 4,600 mm - Interlockings 

- Electrode regulator electro-hydraulic, ABB with EMG valves - Air blast circuit breaker, AEG

 
- Water cooled upper shell - Split shell type 
- Water cooled roof - Movement system – hydraulic 
- Tilting cylinders - Electrode cylinders, arms, clamping devices & their cylinders 
- Roof rotation cylinder - Roof supproting arms 
- Qty. 6 Power supply brass tubes - Off gas system elbow 
- Qty. 5 buckets 
2. Second-hand Reactor & Transformer 
- Reactor 
- Transformer – ABB 37/44,4 MVA, primary voltage 15 kV, TypeKDOR37 000/17.5
Built1990 Load cycle
ITEM 1 
Theoretical (WP) Production Values EAF 1 
Tapping weight 45 t 
El. Energy Cons. (incl. burner) 450 kWh/t 
Power-On Time 41,2 min/heat 
Power-Off Time 22,0 min/heat 
Charging (4 baskets) 10,0 min/heat 
Tapping 4,0 min/heat 
Preparation 2,0 min/heat 
Delays 6,0 min/heat 
Tap to Tap Time 63,2 min/heat 
Available parts 
Tilting cylinders Electrode cylinders, arms, clamping devices and their cylinders 
Interlockings Roof rotation cylinder 
Roof supporting arms 6 power supply brass tubes 
Upper shell Water cooled roof Off gas system elbow 
Missing parts 
Hydraulic center

2 soap oil pumps, 3 electrode movement oil valves, compressor for movements (roof, tilting) Regulation unit 6 high current cables

Accessories available 
5 buckets 
Missing parts 
Hydraulic center2 soap oil pumps 3 electrode mvement oil valves
Compressor for movements (roof, tilting) Regulation unit 6 high current cables