POWER PLANT - 52 MW - GAS & STEAM TURBINE

Description POWER PLANT - 52 MW - GAS & STEAM TURBINE
Ref. No. POWERPLANT200601
Year 1995-2001
Brand GE, ABB, GEC ALSTHOM, MAAG ETC.
Qty. 1 Second-hand 52 MW power plant
Mfc. General Electric, ABB, GEC ALSTHOM, Franco Tosi, MAAG Built
Consists of
Gas Turbine 39 MW Steam Turbine 13 MW 3-Phase Transformer
Electrical Generator Gear Box Heat Recovery Steam Generator
1) Qty. 1 Second-hand 39 MW gas turbine GE LM6000
Mfc. General Electric Model
Working hours after last overhaul 16.483 Starts after last overhaul
Current status long-term preserved
Water injection without PCC single gas fuel nozzle with NO water injection
2) Qty. 1 Second-hand 13 MW steam turbine
Mfc. Franco Tosi Built
Power 12,818 kW Rotation speed of turbine
Rotation speed of alternator 3000 RPM Steam entry - pression
Steam entry - temperature 433°C Steam exit – pressure
Steam re-entry – pressure 4 bar-a Steam re-entry – temperature
3) Qty. 1 Step-up Transformer (3-phase)
Mfc. ABB Built
Nominal power 50 – 87 MVA
4) Qty. 1 Electrical Generator
Mfc. GEC ALSTHOM Type
Current 3364 A Speed
5) Qty. 1 Gear Box
Mfc. MAAG, Switzerland Type
High speed shaft 3611 RPM Low speed shaft
6) Qty. 1 Heat Recovery Steam Generator
Mfc. TBA Built
high pressure cylindrical body and a low pressure body, without post-combustion.
High pressure 4.2 MPa at a temperature of 450°C and a steam flow rate of about 45 TPA
Low Pressure 0.4 MPa at a temperature of 150°C and a steam flow rate of about 11.5 TPA